Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Coluna/Columna ; 19(3): 209-212, July-Sept. 2020. tab, graf
Article in English | LILACS | ID: biblio-1133580

ABSTRACT

ABSTRACT Objective To compare the Schanz screw insertion angle and the loss of the regional kyphosis correction in thoracolumbar burst fractures following posterior short instrumentation surgery. Methods Patients with a thoracolumbar burst fracture between levels T11-L2 were divided into two groups (parallel and divergent) according to the angle formed between the Schanz screw and the vertebral plateau. Regional kyphosis was evaluated in preoperative, immediate postoperative and last follow-up radiographs. Results Of the 58 patients evaluated, 31 had a parallel assembly and 27 had a divergent assembly. When we analyzed the angle of kyphosis, no statistical difference was observed between the pre- and postoperative radiographs. However, a statistical difference in the last follow-up radiographs and in the final loss of the kyphosis correction was confirmed. Conclusion The insertion of Schanz screws with a divergent assembly presents better radiographic results with less loss of kyphosis correction angle when compared with the parallel assembly technique. Level of Evidence III; Retrospective cohort study.


RESUMO Objetivo Comparar o ângulo de inserção do pino de Schanz e os resultados da perda de correção da cifose regional nas fraturas toracolombares do tipo explosão após tratamento cirúrgico com instrumentação curta por via posterior. Métodos Os pacientes com fratura toracolombar do tipo explosão entre os níveis de T11-L2 foram divididos em dois grupos (paralelo e divergente) de acordo com o ângulo formado entre o pino de Schanz e o platô vertebral. Foi avaliada a cifose regional nas radiografias pré-operatória, pós-operatória imediata e do último acompanhamento. Resultados Dos 58 pacientes avaliados, 31 apresentaram uma montagem paralela e 27 uma montagem divergente. Ao analisarmos o ângulo da cifose, não se observou diferença estatística nas radiografias pré- e pós-operatória imediata. Porém, verificou-se uma diferença estatística nas radiografias do último acompanhamento e na perda final de correção da cifose. Conclusões A inserção do pino de Schanz com uma montagem divergente apresenta melhores resultados radiográficos com menor perda do ângulo de correção da cifose quando comparada com a técnica de montagem paralela. Nível de Evidência III; Estudo de coorte retrospectivo.


RESUMEN Objetivo Comparar el ángulo de inserción del tornillo de Schanz y los resultados de la pérdida de corrección de la cifosis regional en las fracturas toracolumbares del tipo explosión después del tratamiento quirúrgico con instrumentación corta por vía posterior. Métodos Los pacientes con fractura toracolumbar del tipo explosión entre los niveles de T11-L2 fueron divididos en dos grupos (paralelo y divergente) de acuerdo con el ángulo formado entre el tornillo de Schanz y la meseta vertebral. Fue evaluada la cifosis regional en las radiografías preoperatoria, posoperatoria inmediata y del último acompañamiento. Resultados De los 58 pacientes evaluados, 31 presentaron un montaje paralelo y 27 un montaje divergente. Al analizar el ángulo de la cifosis, no se observó diferencia estadística en las radiografías pre y postoperatoria inmediata. Sin embargo, se verificó una diferencia estadística en las radiografías del último acompañamiento y en la pérdida final de corrección de la cifosis. Conclusiones La inserción del tornillo de Schanz con un montaje divergente presenta mejores resultados radiográficos con menor pérdida del ángulo de corrección de la cifosis cuando comparada con la técnica de montaje paralelo. Nivel de Evidencia III; Estudio de cohorte retrospectivo.


Subject(s)
Humans , Fracture Fixation , Kyphosis
2.
Coluna/Columna ; 15(1): 78-84, Jan.-Mar. 2016. tab, graf
Article in English | LILACS | ID: lil-779074

ABSTRACT

ABSTRACT The number of fixed segments in the surgical treatment of thoracolumbar burst fractures remains controversial. This study aims to compare the results of short and long fixation in thoracolumbar burst fractures through a meta-analysis of studies published recently. MEDLINE and Cochrane databases were used. Randomized controlled trials and non-randomized comparative studies (prospective and retrospective) were selected. Data were analyzed with the software Review Manager. There was no statistically significant difference in the Cobb angle of preoperative kyphosis. Long fixation showed lower average measurements postoperatively (MD = 1.41; CI = 0.73-2.08; p<0.0001) and in the last follow-up (MD = 3.98; CI = 3.22-4.75; p<0.00001). The short fixation showed the highest failure rates (RD = 4.03; CI = 1.33-12.16; p=0.01) and increased loss of height of the vertebral body (MD = 1.24; CI = 0.49-1.98; p=0.001), with shorter operative time (MD = -24.54; CI = -30.16 - -18.91; p<0.00001). There was no significant difference in blood loss and clinical outcomes. The high rates of kyphosis correction loss with short fixation and the lower correction rate in the immediate postoperative period were validated. There was no significant difference in the blood loss rates because arthrodesis was performed in a short segment in the analyzed studies. The short fixation was performed in a shorter operative time, as expected. No study has shown superior clinical outcomes. The short fixation had worse rates of kyphosis correction in the immediate postoperative period, and increased loss of correction in long-term follow-up, making the long fixation an effective option in the management of this type of fracture.


RESUMO A quantidade de segmentos fixados no tratamento cirúrgico das fraturas toracolombares tipo explosão continua controverso. Este estudo tem como objetivo comparar os resultados da fixação curta e da longa nas fraturas toracolombares do tipo explosão, por meio de uma metanálise dos estudos publicados recentemente. Foram utilizadas as bases de dados MEDLINE e COCHRANE. Foram selecionados estudos controlados randomizados e estudos comparativos não randomizados (prospectivos e retrospectivos). Os dados foram analisados com o software Review Manager. Não houve diferença estatisticamente significante na medida do ângulo de Cobb da cifose pré-operatória. A fixação longa apresentou medidas médias inferiores no pós-operatório (MD = 1,41; IC = 0,73-2,08; p < 0,0001) e no último seguimento (MD = 3,98; IC =3,22-4,75; p < 0,00001). A fixação curta apresentou taxas de falha maiores (RD = 4,03; IC = 1,33-12,16; p = 0,01) e maior perda de altura do corpo vertebral (MD = 1,24; IC = 0,49-1,98; p = 0,001), com menor tempo operatório (MD = -24,54; IC = -30,16 - -18,91; p < 0,00001). Não houve diferença estatisticamente significante na perda sanguínea e nos desfechos clínicos. As taxas elevadas de perda da correção da cifose na fixação curta e a menor taxa de correção no pós-operatório imediato foram validadas. Não houve diferença estatisticamente significante quanto às taxas de perda sanguínea, porque a artrodese foi realizada em um segmento curto nos trabalhos analisados. A fixação curta teve menor tempo operatório, como esperado. Nenhum estudo demonstrou superioridade dos resultados clínicos. A fixação curta apresentou taxas piores de correção da cifose no pós-operatório imediato e maior perda da correção no seguimento a longo prazo, fazendo da fixação longa uma opção efetiva no manejo deste tipo de fratura.


RESUMEN El número de segmentos fijados en el tratamiento quirúrgico de las fracturas toracolumbares tipo explosión sigue siendo controvertido. Este estudio tiene como objetivo comparar los resultados de fijación corta y larga en las fracturas toracolumbares tipo explosión, a través de un meta-análisis de estudios publicados recientemente. Se utilizaron las bases de datos MEDLINE y COCHRANE. Se seleccionaron los ensayos controlados aleatorios y estudios comparativos no aleatorios (prospectivos y retrospectivos). Los datos fueron analizados con el software Review Manager. No hubo diferencia estadísticamente significativa en cuanto a la medida del ángulo de Cobb de la cifosis preoperatoria. Lar fijación larga mostró mediciones promedio más bajas en el postoperatorio (MD = 1,41, IC = 0,73-2,08; p < 0,0001) y en el último seguimiento (MD = 3,98, IC = 3,22-4,75; p < 0,00001). La fijación corta mostró las tasas de fracaso más altas (RD = 4,03, IC = 1,33-12,16; p = 0,01) y una pérdida mayor de la altura del cuerpo vertebral (MD = 1,24, IC = 0,49-1,98; p = 0,001), con un menor tiempo operatorio (MD = -24,54; IC = -30,16 - -18.91; p < 0,00001). No hubo diferencia significativa en la pérdida de sangre y los resultados clínicos. Se validaron las altas tasas de pérdida de corrección de la cifosis con la fijación corta y la menor tasa de corrección en el postoperatorio inmediato. No hubo diferencia significativa en las tasas de pérdida de sangre porque la artrodesis se realizó en un segmento corto en los estudios analizados. La fijación corta tuvo menor tiempo operatorio, como se esperaba. Ningún estudio ha demostrado resultados clínicos superiores. La fijación corta tuvo peores tasas de corrección de la cifosis en el postoperatorio inmediato y mayor pérdida de corrección en el seguimiento a largo plazo, por lo que la fijación larga es una opción efectiva en el manejo de este tipo de fracturas.


Subject(s)
Spinal Fractures/surgery , Arthrodesis , Fracture Fixation , Kyphosis
SELECTION OF CITATIONS
SEARCH DETAIL